RFCS-2 Base Station

Digital Paging Encoder

PIC – microprocessor controlled management system provides more precise supervision and operation bringing major benefits: -

  • Additional teams added to facilitate mobilising according to incident type and firefighter skill set
  • Faster verification of calls, approximately T+2 seconds where T is the time the call arrives at the Fire Station.
  • Automatic reset if certain supervisory conditions are not met (reset time 0.5 seconds)
  • Non-volatile diagnostic log records all events, sequentially, over approximately a seven-day period.
  • Intelligent power management now incorporated within the 2U enclosure.
  • Mains fail message repeated at programmable intervals.
  • Low battery alarm given at 50% battery capacity remaining
  • Visual indication on front panel of mains failure and eventually, low battery
  • Battery support in excess of 36 hours at Home Office (MG-4) specification regime – 30 calls in 24 hours, that’s a call every 48 minutes. In more practical terms, battery support is up to 100 hours.

 

Digital Transmitter

  • Frequency range 146-174 MHz
  • Multi-channel digital transceiver with 25kHz channel spacing
  • Able to change channel under software control
  • PC Programmable
  • RS 232 interface
  • Frequency stability ± 3ppm
  • Optional dual channel operation - wide area paging in addition to Firefighter Alerting

 

The complete RFCS-2, including 17A/H standby battery, is housed in a 19” rack mountable enclosure, 2U high and 400mm deep.